Sign In | Join Free | My burrillandco.com
Home > Foam Fire Suppression System >

Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment

    Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers
     
    Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers
    • Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers
    • Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers
    • Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers
    • Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers
    • Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers
    • Buy cheap Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment from wholesalers

    Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment

    Ask Lasest Price
    Brand Name : XINGJIN
    Model Number : XJ-QEO-006
    Certification : CCC,CAC,ROHS
    Price : Pricing based on quantity
    Payment Terms : T/T, L/C
    Supply Ability : 30000set/month
    Delivery Time : 15-20days
    • Product Details
    • Company Profile

    Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment

    Professional Novec 1230 Cylinder Filling Machine for Fire Suppression Systems


    Product Description:
    The perfluorohexanone fire extinguishing agent filling equipment is a professional device that combines efficiency, safety, and precision, suitable for the maintenance and installation of perfluorohexanone fire extinguishing systems. Equipped with nitrogen pressure reduction, a filling pressure alarm, a vacuum system, and a reserved interface for weight alarm nodes, the equipment supports a variety of gas cylinder sizes, ensuring airtightness and accuracy during the fire extinguishing agent filling process.

    Equipment valve body function​:

    F1 Pressure Reducing Valve
    Control the pressure of nitrogen when it enters the system to ensure a stable and safe filling process.
    F2 pressure relief valve
    Release excess pressure in an emergency to protect equipment and gas cylinders from high pressure damage.
    F3 Chemical Storage Valve
    Control the flow of fire extinguishing agent from the agent storage tank to the filling cylinder.
    F4 Nitrogen Storage Valve
    Control the nitrogen gas from the storage tank into the equipment pipeline to provide pressure for filling the fire extinguishing agent.
    F5 gas cylinder valve
    Used to connect fire extinguishing agent cylinders and control the opening or closing of the cylinder fluid channel.
    F6 Vacuum Valve
    Used to open or close the extraction of air from the gas cylinder to reduce the pressure inside the cylinder and ensure the purity of the fire extinguishing agent.
    F7 valve
    Control the flow of perfluorohexanone into the gas cylinder
    F8 valve
    Controlled access to gas cylinders
    F9 valve
    Control the passage of nitrogen into the gas cylinder and provide pressure for the gas cylinder.


    Heptafluoropropane filling operation:

    1 After the cylinder is valved, move it to the filling room. Secure the cylinder and connect the piping between the cylinder and the filling station. Adjust the electric contact pressure gauge alarm and the pressure reducing valve outlet pressure. Open the cylinder container valve and slowly open nitrogen valve F2 to fill with nitrogen, controlling the pressure increase rate to no more than 1 MPa/min, until the pressure reaches the specified maximum operating pressure (see Appendix 3, "Test Pressure Comparison Table" for details). Close the cylinder container valve and move the cylinder to the pressure test room for a cylinder seal test.
    2 After the cylinder seal test passes, move it to the filling room's platform scale. Secure the cylinder and connect the piping between the cylinder and the filling station. Open the cylinder container valve and open the pressure relief valve F4 on the filling station to relieve the pressure. After pressure relief is complete, pressurize the filling station vacuum button and simultaneously open vacuum valve F5. Start the vacuum pump to evacuate the cylinder. When the pressure gauge pointer approaches -0.09 MPa and stabilizes, close vacuum valve F5 and the vacuum pump in sequence.

    For more detailed operating instructions please contact us!

    Vacuum control schedule:
    Volume
    8L-30L
    40L
    70L
    90L
    100L
    120L
    150L
    180L
    Minimum vacuum time
    30s
    40S
    50S
    56S
    60S
    65S
    78S
    93S


    Why Choose Us




    Quality Heptafluoropropane perfluorohexanone fire extinguishing agent filling equipment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Xingjin Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)