Sign In | Join Free | My burrillandco.com
Home > FM200 Gas Suppression System >

Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution

    Buy cheap Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution from wholesalers
     
    Buy cheap Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution from wholesalers
    • Buy cheap Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution from wholesalers
    • Buy cheap Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution from wholesalers
    • Buy cheap Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution from wholesalers
    • Buy cheap Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution from wholesalers
    • Buy cheap Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution from wholesalers

    Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution

    Ask Lasest Price
    Brand Name : XINGJIN
    Model Number : 4.2MPa/5.6MPa
    Certification : CCC,ROHS,CAC
    Price : USD480-520/set
    Payment Terms : T/T,L/C
    Supply Ability : 30000set/month
    Delivery Time : 15-20days
    • Product Details
    • Company Profile

    Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution

    Multi-Zone Multi-Cylinder FM200 Fire Suppression System

    Product Overview

    The Multi-Zone Multi-Cylinder FM200 Pipe Network Fire Suppression System is an advanced clean agent fire protection solution designed for critical facilities such as data centers, server rooms, communication facilities, electrical rooms, archives, and museums.

    The system uses multiple agent cylinders connected to a centralized pipe network, allowing one system to protect multiple hazard zones efficiently.

    When a fire is detected, the fire detection system activates the control panel, releasing FM200 extinguishing agent within 10 seconds through the piping network. The agent quickly suppresses flames and interrupts the combustion chain reaction, protecting valuable assets and sensitive equipment.

    The system provides fast fire suppression, zero residue, non-conductive protection, and safe operation for electronic equipment, making it an ideal solution for high-value facilities.

    Key Advantages

    Fast Fire Suppression

    The system discharges extinguishing agent within 10 seconds, ensuring rapid fire suppression.

    Multi-Zone Protection

    One system can protect multiple hazard zones, improving efficiency and reducing installation costs.

    Clean Agent – No Residue

    FM200 leaves no residue after discharge, protecting sensitive electronics.

    Safe & Environmentally Friendly

    Safe for equipment and suitable for occupied environments.

    Centralized Pipe Network System

    The pipe network allows centralized distribution of the extinguishing agent.

    Working Principle

    The system consists of a fire detection system, control panel, cylinder bank, and pipe network.

    When fire detectors sense smoke or heat:

    1. Fire alarm control panel receives the signal

    2. Pre-discharge alarm is activated

    3. Solenoid valve opens the cylinder valve

    4. FM200 agent flows through the pipe network

    5. Nozzles discharge the agent into the hazard area

    6. The agent reaches extinguishing concentration

    This process suppresses fire rapidly and prevents re-ignition.

    Applications

    Typical Applications

    • Data Centers

    • Server Rooms

    • Telecommunications Facilities

    • Electrical Rooms

    • Museums

    • Libraries

    • Archives

    • Control Rooms

    • Power Distribution Rooms

    System Components

    Main Components

    • FM200 Agent Cylinders

    • Cylinder Valves

    • Electric Actuator

    • Selector Valves

    • Pipe Network

    • Discharge Nozzles

    • Fire Alarm Control Panel

    • Smoke & Heat Detectors

    • Audible & Visual Alarms


    Technical Specifications

    Fire extinguishing agentFM200 (HFC-227ea)
    Spraying time≤10 s
    Fire extinguishing methodsTotal flooding fire extinguishing
    Working temperature-10℃ ~ 50℃
    Drive modeElectric start / Air start
    Number of protection zonesMulti-zone protection
    System structurePipeline network type
    Control methodAutomatic / Manual / Mechanical Emergency

    Why Choose Our FM200 System

    Our Advantages

    • International fire safety standards compliance

    • Professional fire protection engineering experience

    • OEM / ODM service available

    • Customized system design support

    • Global project delivery capability

    Request a Quote

    Contact us today to get:

    • System design support

    • Project quotation

    • Technical documentation

    • OEM / ODM cooperation

    Quality Centralized FM200 Fire Pipe Network - High Efficiency Gas Suppression System Solution for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Xingjin Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)