Sign In | Join Free | My burrillandco.com
Home > Fire Safety Equipments >

Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use

    Buy cheap Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use from wholesalers
     
    Buy cheap Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use from wholesalers
    • Buy cheap Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use from wholesalers
    • Buy cheap Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use from wholesalers
    • Buy cheap Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use from wholesalers

    Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use

    Ask Lasest Price
    Brand Name : XINGJIN
    Model Number : J-SAP-JBF4121A
    Certification : CCC;GB/T 3836.1-2021;GB/T 3836.4-2021;GB 19880-2005
    Price : USD3-4/pc
    Payment Terms : T/T,L/C
    Supply Ability : 300000 sets per month
    Delivery Time : 15-20days
    • Product Details
    • Company Profile

    Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use

    Product Overview

    This explosion-proof manual fire call point is a manual alarm station specially designed for hazardous areas with flammable gases. By pressing the operation panel, it sends a fire signal to the fire alarm control panel. The product adopts intrinsically safe explosion-proof design with Ex ib IIC T6 Gb marking, suitable for Zone 1 and Zone 2 hazardous areas containing IIA, IIB, IIC class T1-T6 combustible gases. Built with a microprocessor and non-polarized two-bus technology, the transmission distance can reach up to 1000 meters. It can seamlessly connect with controllers, providing reliable manual fire alarm functionality for chemical plants, petroleum facilities, gas stations, and similar locations.

    Applicable Places

    This product is widely used in the following commercial and industrial premises:

    • Petrochemical Industry: Refineries, chemical plants, oil depots, gas stations, filling stations

    • Gas Facilities: Natural gas stations, LPG stations, gas pressure regulating stations

    • Industrial Plants: Spray painting workshops, printing workshops, lithium battery production workshops

    • Hazardous Material Warehouses: Chemical warehouses, flammable material storage areas

    • Laboratories: Chemical laboratories, hazardous material storage areas in research institutions

    • Commercial Support Areas: Underground parking lots, boiler rooms, electrical rooms with combustible gas risks

      Core Advantages

      1. Intrinsically Safe Explosion-Proof Certified

      The product has passed strict inspection by the National Center for Quality Supervision and Testing of Explosion-Proof Electrical Products (CQST) with Ex ib IIC T6 Gb marking, suitable for explosive environments containing IIA, IIB, IIC class T1-T6 combustible gases. The intrinsically safe design requires connection with a safety barrier, ensuring that even in case of failure in hazardous areas, it will not generate sparks or high temperatures sufficient to ignite explosive gases, providing reliable safety assurance for high-risk places like petrochemical facilities.

      2. Microprocessor Control Stable Performance

      Built with a high-performance microprocessor and SMT surface mount technology, the components have good consistency and high reliability. Intelligent algorithms accurately identify button activation status, avoiding false alarms. Electronic addressing allows on-site programming with a dedicated encoder, with an addressing range of 1-200 points, facilitating engineering commissioning and later maintenance.

      3. Non-Polarized Two-Bus Long-Distance Communication

      Adopting non-polarized two-bus technology, the standby current is ≤0.3mA and alarm current ≤1mA, achieving extremely low power consumption. The communication distance can reach up to 1000 meters, supporting coverage of large industrial areas. The non-polarized bus design eliminates the need for polarity distinction during wiring, significantly reducing installation difficulty and labor costs.

      4. Plug-In Structure Easy Maintenance

      The button body adopts a plug-in structure design. During installation, simply insert the encoded body into the base and secure with self-tapping screws. Disassembly and maintenance are equally simple and quick. The operation panel must be reset with a special key after being pressed, preventing unauthorized operation and ensuring system management security.

      5. Clear Indication Easy Status Recognition

      The panel features a red fire alarm indicator light that flashes momentarily in normal monitoring status and becomes steady red when activated. The status display is clear and intuitive. Even in dimly lit industrial environments, the working status and alarm status of the button can be easily identified.


      Explosion-Proof Safety Instructions

      This product is an intrinsically safe explosion-proof device. The following requirements must be strictly observed during use:

      • Must be used with a safety barrier that has obtained an explosion-proof certificate

      • The positive and negative terminals of the safety barrier input must not be reversed

      • When multiple safety barriers are used in the same circuit, they must be connected in parallel at the input end; cascade connection is prohibited

      • Never wipe the device housing with a dry cloth in explosive environments

      • For cleaning, perform in a well-ventilated area without gas leakage, and wipe with a wrung damp cloth

      • This product is a single-use device; once damaged, it cannot be repaired


      Technical Specifications



      ParameterSpecification
      Operating VoltageDC 18-28V (via safety barrier)
      Standby Current≤0.3mA (24V)
      Alarm Current≤1mA (24V)
      Explosion-Proof MarkingEx ib IIC T6 Gb
      Addressing MethodElectronic encoder
      Addressing Range1-200
      Indicator LightStandby: Flashing momentarily; Alarm: Steady red
      Wiring MethodTwo-bus, non-polarized
      Transmission Distance≤1000m (conductor cross-section ≥1.0mm²)
      Operating Temperature-10℃ to +55℃
      Storage Temperature-30℃ to +75℃
      Relative Humidity≤95% (40±2℃)
      Dimensions90mm×90mm×52mm
      Weight170g
      Mounting Hole Distance60mm (compatible with 50mm)
      Recommended WireRVS 2×1.5mm² twisted pair

      Commercial Application Value

      Ensure Safety in High-Risk Places: Intrinsically safe explosion-proof design meets fire protection requirements for hazardous areas such as petrochemical and gas facilities, effectively preventing explosion risks.

      Reduce False Alarm Losses: Microprocessor intelligent recognition accurately identifies button activation, reducing production interruptions and unnecessary evacuations caused by false alarms.

      Save Construction Costs: Non-polarized two-bus design simplifies wiring processes, saving cable and labor costs; long-distance communication capability reduces the need for relay equipment.

      Efficient Management: Special key reset prevents unauthorized operation; plug-in structure facilitates maintenance; clear indicator light status reduces operational difficulty.


      Installation and Usage Instructions

      1. Wiring Requirements: Use RVS 2×1.5mm² twisted pair, loop resistance ≤20Ω

      2. Address Setting: Write address code (1-200) using a dedicated encoder before installation

      3. Base Installation: Secure the base to the wall using a pre-embedded box or expansion bolts, mounting hole distance 60mm

      4. Wiring Method: Connect loop bus L1 and L2 to terminals 1 and 2, no polarity requirement

      5. Body Installation: After wiring inspection, insert the encoded button body into the base and secure with self-tapping screws

      6. Reset Operation: After alarm, the operation panel must be reset using the special key


      Precautions

      • Must be used with a safety barrier; never connect directly to the controller bus

      • Safety barrier parameter matching must follow Uo≤Ui, Io≤Ii, Po≤Pi principles

      • Never disassemble or wipe the device in explosive environments

      • This product is a single-use device; once damaged, it cannot be repaired

      • Installation should comply with GB3836.15-2010 regulations and be performed by professionals

    Quality Explosion- Proof Manual Fire Alarm Button For Hazardous Area Use for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Xingjin Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)