    High-pressure IG541 Gas Fire Extinguishing System Components

    Ask Lasest Price
    Brand Name : Xingjin
    Model Number : QMH15/80, QMH15/90
    Certification : CAL,CMA,CNAS,ILAC-MRA,CCC
    Price : negotiation
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 300 sets per month
    Delivery Time : 10-15 working days
    • Product Details
    • Company Profile

    High-pressure IG541 Gas Fire Extinguishing System Components

    Pipe Network Type of IG541 Automatic Fire Suppression System

    Description:

    The IG541 mixed gas fire extinguishing agent is a colorless, odorless, non-toxic, non-conductive, and purely "green" compressed gas. It is composed of naturally occurring gasesnitrogen, argon, and carbon dioxidewith readily available raw materials. During fire suppression, it does not obstruct visibility, nor does it generate temperature differences or corrosive decomposition products. The release of this agent simply returns natural gases back into the environment; it has no ozone-depleting potential (ODP), does not contribute to the greenhouse effect, and produces no atmospheric-damaging chemicals. Unlike halon-based or alternative extinguishing agents, it avoids toxicity issues associated with their use during fire suppression, making it an ideal choice for areas with frequent human activity.


    High-pressure IG541 Gas Fire Extinguishing System Components
    System components, structure and parameters:

    6. Electromagnetic driver:

    6.1 Purpose

    The electromagnetic container valve is installed on the starting gas cylinder to seal the starting gas inside. During a fire, the controller issues a fire suppression command, activating the electromagnet within the valve to open it and release the starting gas. The gas then flows through the starting pipeline, activating the corresponding selection valve and container valve to release the fire extinguishing agent for suppression.

    Model _ Structural Diagram and Main Performance Parameters:

    Electromagnetic driver model

    rated voltage

    rated current

    Rated suction

    Power On Continuity Rate

    MFZ1-90F/24V

    DC24±3V

    1.5A

    90N

    100%

    High-pressure IG541 Gas Fire Extinguishing System Components

    7. Selection valve (also called distribution valve):

    Structure: The selection valve primarily consists of a valve body, a drive cylinder, and other components.

    Working Principle: The selection valve is used in combined distribution systems. When a fire alarm occurs in the protection zone corresponding to the selection valve, the fire alarm controller outputs a DC 24V current to open the drive valve associated with the distribution valve. The activation gas flows through the control air pipe, which opens the selection valve; subsequently, the gas passes through the control air pipe and a gas check valve to activate the fire extinguishing agent container valve. The fire extinguishing agent is then delivered to the protection zone via the collection pipe, selection valve, and distribution network. In emergency situations, the handle may be operated manually to open the selection valve; however, under normal conditions, personnel must not operate the handle to prevent unintended activation. The external diagram is shown below:

    model

    Nominal diameter (mm)

    Nominal working pressure (MPa)

    Air tightness test (MPa)

    HXZ40/17.2

    40

    17.2

    17.2

    HXZ32/17.2

    32

    17.2

    17.2

    HXZ50/17.2

    50

    17.2

    17.2

    HXZ65/17.2

    65

    17.2

    17.2

    HXZ80/17.2

    80

    17.2

    17.2

    High-pressure IG541 Gas Fire Extinguishing System Components

    8. Metal hose

    8.1 Purpose: Provides a flexible connection between the container valve and the check valve, mitigating flow impact on the mixed gas fire extinguishing agent.

    8.2 Structure: Constructed from stainless steel corrugated pipes and stainless steel wire mesh. The connecting hose serves as the pipeline linking the container valve and the liquid check valve, providing pressure buffering functionality. It primarily consists of a steel-wire braided hose and hose fittings. The external appearance and dimensions of the connecting hose (which can be custom-made according to specific requirements) are as follows:

    model

    Nominal diameter

    mm

    design pressure

    MPa

    Import and Export Size

    length L

    HRG15/17.2

    15

    17.2

    M30×1.5

    450mm

    High-pressure IG541 Gas Fire Extinguishing System Components






    9. One-way valve

    9.1 Purpose: Installed on the IG-541 collector tube to prevent backflow of the mixed gas from the tube.

    9.2 Structure: Composed of components such as the valve body, valve core, and spring. It features a novel design, flexible operation, excellent sealing performance, and low fluid resistance.

    9.3 Application: The flexibility and sealing performance of the valve core should be inspected regularly.

    model

    Nominal diameter

    mm

    maximum working pressure

    MPa

    Import size

    outlet size

    HYD15/17.2

    14

    17.2

    R3/4

    M30×1.5

    High-pressure IG541 Gas Fire Extinguishing System Components

    10. Pneumatic check valve

    10.1 Purpose: For use on the control air line during system startup.

    10.2 Structure: Composed of components such as the valve body, valve core, and spring, featuring a novel design, smooth operation, excellent sealing performance, and easy installation.

    10.3 Application: The pneumatic control piping system employs clamp-type pipe fittings for connections, using φ8×1 copper tubes. The pneumatic check valve requires regular inspection of the valve core's flexibility and sealing performance.

    model

    Nominal diameter

    mm

    design pressure

    MPa

    open

    pressure MPa

    Import and Export Size

    HQD6/6.6

    6

    17.2

    0.2MPa

    M14×1.5


    High-pressure IG541 Gas Fire Extinguishing System Components

    11. Pressure Signal Feedback Device

    11.1 Purpose: Installed at the outlet end of the selection valve (for standalone systems without a selection valve, it can be mounted on the manifold). When the mixed gas fire extinguishing agent is released, the pressure switch activates, sending signals to the vent light, audio-visual alarm, and control center.

    11.2 Structure: Composed of a valve body, piston, and microswitch, among other components. It features compact size, lightweight design, and high flexibility and reliability.

    11.3 Application: Before installation, inspect the piston's operation and measure the microswitch's performance. During installation, ensure the housing is not subjected to any mechanical stress.

    model

    design pressure MPa

    Minimum action pressure (MPa)

    size for connection

    HXF0.8/17.2

    17.2

    0.8

    R1/2

    High-pressure IG541 Gas Fire Extinguishing System Components

    12. Collection pipe

    12.1 Purpose: A mixed gas fire extinguishing agent collected from multiple containers is then transported via the main pipeline to the distribution network within the protected area.

    12.2 Structure: The collector pipe is fabricated by welding seamless steel pipes and fittings, with an overall galvanizing treatment. The fitting for the check valve can be manufactured in either single-row or double-row configurations as required.

    12.3 Application: The collector tube shall be securely fastened to the cylinder bracket using standard U-bolts.


    13. Collection pipe safety valve

    13.1 Application: Installed on the collector pipe. Since the combined distribution system employs a selection valve, the collector pipe forms a closed section. When mixed gas accumulates, significant pressure is generated due to temperature effects; therefore, a safety valve is installed at the rear end of the collector pipe.

    13.2 Structure: Composed of a valve body and a safety diaphragm. Features a novel design with high safety and reliability.

    model

    Nominal diameter

    mm

    design pressure

    MPa

    Pressure relief action pressure (MPa)

    Import and Export Size

    HXA23

    6

    17.2

    23±5%

    R1/2

    High-pressure IG541 Gas Fire Extinguishing System Components

    14. Steel cylinder stand

    14.1 Purpose: Used to secure the IG-541 fire extinguisher unit.

    14.2 Structure: The cylinder stand is constructed from rectangular pipes, featuring exquisite craftsmanship, aesthetic appeal, and robust reliability.

    14.3 Application: The cylinder rack is detachable for transportation and can be assembled on-site. The installation site should be level and smooth; if necessary, it may be secured with anchor bolts. The collector pipe should be fixed above the cylinder rack. During assembly, ensure the vertical alignment of the cylinder rack is properly adjusted.

    specifications

    project

    80

    90

    Cylinder volume V (L)

    80

    90

    Container spacing (mm)

    350

    350

    Cylinder stand length L (mm)

    120+370×(n-1)

    Cylinder stand width B (mm)

    325 single-bottle pack

    height of the gas cylinder stand H (mm)

    1900

    2100

    15. Nozzle

    The nozzle is one of the critical components of the system. Its specifications should be determined based on the specific requirements of the protected area.

    15.1 Structure: The nozzle is primarily composed of a nozzle body. The external appearance is shown below:

    Working principle: The nozzle is installed within the protected area to spray the atomized fire extinguishing agent, ensuring uniform coverage throughout the area.

    High-pressure IG541 Gas Fire Extinguishing System Components

    16. Low-relief high-seal valve

    use :

    The low-leakage high-seal valve is installed in the startup pipelines of each zone within the gas system. When a minor leak occurs in the startup device (with pipeline pressure 0.1 MPa), the leaking gas is automatically discharged, preventing gas accumulation and pressure buildup that could trigger unintended system malfunctions.

    During system operation, as the pressure in the startup pipeline increases rapidly, the low-pass high-resistance valve automatically closes to ensure proper system startup.

    16.1 External appearance diagram of the low-discharge high-seal valve:

    model

    Nominal diameter (mm)

    Nominal working pressure (MPa)

    Air tightness test (MPa)

    Close Pressure

    (MPa)

    HDG0.3/6.6

    6

    6.6

    6.6

    0.3±0.03

    High-pressure IG541 Gas Fire Extinguishing System Components

    16.2 External appearance diagram of the low-discharge high-seal valve:

    model

    Nominal diameter (mm)

    Nominal working pressure (MPa)

    Air tightness test (MPa)

    Close Pressure

    (MPa)

    HDGO.3/17.2

    6

    17.2

    17.2

    0.3±0.03

    High-pressure IG541 Gas Fire Extinguishing System Components

    17. Pressure relief device

    17.1 Purpose: For gas pressure reduction of IG-541.

    17.2 Structure: Composed of inlet and outlet flanges, pressure-reducing orifice plates, and sealing rings. Features compact size, excellent sealing performance, and stable, reliable operation.

    model

    specifications

    Design pressure (MPa)

    Pressure relief plate aperture diameter

    HJYB13.8/40

    DN40

    17.2

    Calculated based on actual figures

    HJYB13.8/32

    DN32

    17.2

    Calculated based on actual figures

    HJYB16.7/50

    DN50

    17.2

    Calculated based on actual figures

    HJYB21.5/65

    DN65

    17.2

    Calculated based on actual figures

    HJYB26.4/80

    DN80

    17.2

    Calculated based on actual figures


    High-pressure IG541 Gas Fire Extinguishing System Components


    Quality High-pressure IG541 Gas Fire Extinguishing System Components for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangzhou Xingjin Fire Equipment Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)