Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers

    Buy cheap Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers from wholesalers
     
    Buy cheap Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers from wholesalers
    • Buy cheap Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers from wholesalers
    • Buy cheap Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers from wholesalers
    • Buy cheap Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers from wholesalers
    • Buy cheap Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers from wholesalers
    • Buy cheap Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers from wholesalers

    Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers

    Ask Lasest Price
    Model Number : JGQ2/1.6-XJ
    Delivery Time : 15-20days
    Certification : GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1
    Payment Terms : T/T,L/C
    Brand Name : XINGJIN
    Price : USD480-520/set
    Supply Ability : 30000set/month
    • Product Details
    • Company Profile

    Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers

    Product Introduction

    The Server-Rack Fire Suppression Unit is an innovative automatic fire suppression system independently developed by our company. It is specifically designed for protecting equipment cabinets and enclosures. This unit is also known as a temperature-sensing detection and extinguishing integrated device or a pre-engineered fire extinguishing unit.

    The unit integrates the following components into a single, self-contained assembly:

    • Fire extinguishing agent storage vessel
    • Delivery piping and discharge nozzle
    • Enclosure housing
    • Pressure indicator
    • Fire detector(s)
    • Signal feedback device

    One Server-Rack Fire Suppression Unit can protect a single equipment cabinet or, depending on the configuration, multiple cabinets within a defined enclosure.

    Fire Extinguishing Agent Options

    The device can be charged with either of the following clean agents:

    • HFC-227ea (FM200)
    • FK-5-1-12 (Novec 1230)

    Both FM200 and Novec 1230 are clean gas extinguishing agents that operate primarily through chemical fire suppression, supplemented by physical cooling effects. They are colourless, odourless, low-toxicity, non-conductive, and leave no residue on protected equipment. They will not cause damage to property or precision facilities. With relatively low extinguishing concentrations, they provide reliable suppression for Class B fires, Class C fires, and electrical fires.

    Detection Technology

    The Server-Rack Fire Suppression Unit incorporates two independent detection methods:

    1. Temperature-sensing glass bulb
    2. Fire detection tube

    This design eliminates the need for a conventional fire detection system comprising smoke detectors, heat detectors, and a separate fire control panel. Our integrated approach offers the following benefits:

    • Enhanced detection and extinguishing performance
    • Better adaptability for installation within equipment cabinets
    • Reduced space requirements
    • No interference with existing cabinet components or airflow
    Server-rack fire suppression unit showing integrated storage vessel, discharge nozzle, pressure indicator, and detection tube assembly

    Applications

    The Server-Rack Fire Suppression Unit is suitable for the following applications:

    Industry / ApplicationCabinet / Equipment Type
    IT & Computer SystemsServer cabinets, data storage racks
    Telecommunications & CommunicationsTelecom server cabinets, transmission equipment racks
    Banking & FinanceBank equipment control cabinets
    Industrial & MechanicalControl cabinets across various industries and sectors

    Working Principle

    The Server-Rack Fire Suppression Unit offers two temperature-based activation modes:

    Mode 1: Temperature-Sensing Glass Bulb

    When the ambient temperature inside the protected enclosure reaches the rated activation temperature of the glass bulb (standard setting: 68 °C, with other temperature ratings available upon request), the bulb bursts instantly. This opens the agent release port, and the stored gas extinguishing agent is immediately discharged through the nozzle. The agent cools the protected area and suppresses the fire.

    Mode 2: Fire Detection Tube

    When the detection tube is exposed to a heat source and reaches its activation temperature (160 °C ± 10 °C), the pressurised gas inside the tube expands rapidly. The tube then ruptures at the point of highest temperature (the fire origin). This pressure drop activates the storage vessel, and the extinguishing agent is discharged through the rupture point of the tube, providing localised cooling and fire suppression.


    Main Technical Parameters and Characteristics
    4.1 Model and Specifications of Server-Rack Fire Suppression Unit
    SpecificationSize L×W×H (mm)Volume of Storage Container (L)Filling Density (kg/m³)Storage Pressure (MPa)Max Working Pressure (50 °C; MPa)Applicable Ambient
    JGQ2/1.6-XJ745×425×422≤11501.62.50 °C – 50 °C
    4.2 Technical Parameters of Fire Detecting Tube
    Outer DiameterInner DiameterThicknessFusion Point
    Φ6 mm4 mm1 mm160 °C ± 10 °C
    Fire detection tube detail showing outer diameter, inner diameter, wall thickness, and fusion point specifications
    Quality Integrated No Power Required Rack Fire Suppression Unit with 2L Server Rack Fire Suppression System for Data Centers for sale