| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Model Number : | QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2, QMP70/5.6, QMP90/5.6, QMP120/5.6 |
| Brand Name : | Xingjin / OEM |
| Certification : | CAL,CMA,CNAS,ILAC-MRA,CCC |
| Price : | negotiation |
| Payment Terms : | T/T, L/C |
| Supply Ability : | 30000 set system |
| Delivery Time : | 15-20 working days after payment or receipt of L/C |
HFC-227ea (also known as FM200) is a colorless, odorless, and clean fire suppression agent used widely around the world. Compared to other fire agents such as CO2 and halon, HFC-227ea is more environmentally friendly because it does not harm the ozone layer. HFC-227ea gas has an ozone depletion potential of zero.
Furthermore, HFC-227ea possesses all the advantages of other fire agents — it is non-toxic, non-corrosive, and electrically insulating — making it widely regarded as the optimum substitute for halon series agents.
HFC-227ea can extinguish fires efficiently within 10 seconds without leaving any residue, so users do not need to spend additional money and time cleaning up the area after the system is activated.
| No. | Specifications | 4.2 MPa System | 5.6 MPa System |
|---|---|---|---|
| 1 | Capacity | 40 L, 70 L, 100 L, 120 L, 150 L, 180 L | 70 L, 90 L, 120 L |
| 2 | Device Model | QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2 | QMP70/5.6, QMP90/5.6, QMP120/5.6 |
| 3 | Filling Pressure | 4.2 MPa | 5.6 MPa |
| 4 | Max Filling Rate | 0.95 kg/L | 1.08 kg/L |
| 5 | Discharge Time | ≤ 10 s | |
| 6 | Power | DC 24 V / 1.5 A | |
| 7 | Nitrogen Driving Device | 6.0 ± 1.0 MPa | |
| 8 | Storage Surroundings | Temperature: −10 ~ 50 °C Relative Humidity: ≤ 97% | |
| 9 | Proportion | ≤ 800 m² | |
| 10 | Volume | ≤ 3600 m³ | |

The pipe network type FM200 fire suppression system consists of three main parts: the pipe network, the fire fighting equipment, and the electrical elements. The electrical elements form a set of detecting devices and always play a subsidiary role in each system.
The electrical elements include several control panels, manual buttons, discharge indicator lights, alarm bells, sounder with light units, smoke detectors, and heat detectors.
The main part of the system is the fire fighting equipment, which is formed by the following components:

The pipe network type FM200 fire suppression system is suitable for a wide range of places and several kinds of fires. The following are some examples for customer reference:
Each system is packed with polyfoam first and then placed into a wooden case. When required to meet customer or safety requirements, we will also make a pallet for the goods.


A1: We are a manufacturer.
A2: Yes, we welcome your own design and drawing.
A3: Our factory is located in Shilou, Panyu, Guangzhou, Guangdong, China. Of course — we always welcome and look forward to your visit.
A4: Thanks to convenient transportation in the area, you can take a taxi or come by subway. If you come by subway, take Line 4 and get off at Shiqi Station. Then walk out of the station and take Bus No. 126, getting off at Yuexi Station.
|